operation
This allows a proprietary parameter to be added or deleted from a particular
message type (see ‘message type’ parameter) as shown in the table below:
Value Operation Description
0 Add Add the proprietary parameter to the message type.
1 Delete Delete the proprietary parameter from the message type.
Other N/A All other values reserved and currently if used will cause an error
indication with status ISPE_BAD_PARAM to be returned.
message type
The message type which the custom parameter must be supported or
removed from.
parameter types
The name of the parameter as used in the network. A maximum of 24
proprietary parameters may be specified in this message. A value of zero in
the array of parameter types indicates that the byte is empty (i.e. no
parameter specified).
8.7 Change Circuit Group Configuration Request
This message will allow certain parameters relating to a specific circuit group
(configured) to be changed.
Message Header
structure MSG
type ISP_MSG_CNG_GRP (0x7715)
id gid
src Originating module ID
dst ISUP module ID
rsp_req Sending layer's bit set if confirmation required
hclass 0x00
status 0x00
err_info 0x00
len 10
Seitenansicht 142