The following optional parameters are supported in ITU-T mode only:
Access transport
Call transfer number
Generic notification
Message compatibility information
Parameter compatibility information
6.6.11 Facility Confirmation
This message is issued by ISUP to indicate that the remote party has
accepted (provided) or rejected a supplementary service previously requested
by the user during the active (speech) stage of a call. This primitive may
take two forms.
Accepted
Message type
FAA (Facility Accepted Message)
Mandatory parameters
Facility indicator
User to user indicators
Optional parameters
The following parameters are supported in ITU-T mode only:
Call reference
Connection request
Parameter compatibility information
Rejected
Message type
FRJ (Facility Rejected Message)
Mandatory parameters
Facility indicator
Cause indicators
Optional parameters
Call reference
The following optional parameters are supported in ITU-T mode only:
User to user indicators