Welltech Dialogic SS7 Protocols ISUP Bedienungsanleitung Seite 73

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 203
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 72
Dialogic
®
SS7 Protocols ISUP Programmer's Manual Issue 15
73
The following optional parameters are supported in ANSI mode:
Network termination
6.6.26 Resume Indication
This primitive is used by ISUP to indicate that a call that had been suspended
is now resuming.
Message type
RES (Resume Message)
Mandatory parameters
Suspend/resume indicators
Optional parameters
Call reference
6.6.27 Segmentation Indication
Note: This message is only applicable to ITU-T operation
This primitive contains the second segment of an ISUP message.
Message type
SGM (Segmentation Message)
Mandatory parameters
None
Optional parameters
Access transport
User-to-user information
Message compatibility information
Generic digit
This parameter may be repeated (see
Appendix E: ISUP Repeat
Parameters
on page 197).
Generic notification
This parameter may be repeated (see Appendix E: ISUP Repeat
Parameters
on page 197).
Generic number
This parameter may be repeated (see
Appendix E: ISUP Repeat
Parameters
on page 197).